Hot Runner Temperature Controllers Guide
- Extrusion Barrels & Dies
- Injection Moulding
- Blow Moulding Barrels
- Blown Film
- Compounding
- Rubber Machinery
Hot Runner Systems - Description Guide
The Hot Runner System control modules are fully automatic PID controllers with on board
diagnostics for Open, Shorted, or Reversed thermocouple.
The Hot Runner System also features LED's for under temperature or over temperature indication, Heat load on/off, Ramp start, and Open or closed loop operation. The display can also be set for set point or process temperature indication and a +/- 3 degree indicator flashes when process temperature is within 3 degrees of setpoint.
Hot Runner System control modules are also designed for full communication capability with alarm and standby module.
The Hot Runner System also features LED's for under temperature or over temperature indication, Heat load on/off, Ramp start, and Open or closed loop operation. The display can also be set for set point or process temperature indication and a +/- 3 degree indicator flashes when process temperature is within 3 degrees of setpoint.
Hot Runner System control modules are also designed for full communication capability with alarm and standby module.
Hot Runner System Features Review:
- Microprocessor based controllers
- Automatic tuning PID Control
- Touch pad front panel controls
- Soft start ramp up standard feature
- Auto or manual mode available thermocouple status indicator
- Current indication setpoint or process indication
- Under/over temperature indication
How To Order A Hot Runner Control System-Technical Letter.pdf
Hot Runner System Specifications:
Voltage. . . . . . . . . . . . . . . .120 or 240 volts |
Output Current/ Watts. . . . .15 amps 3600 watts at 240 1800 at 120 |
Input. . . . . . . . . . . . . . . . . .Type J thermocouple Grounded or ungrounded |
T/C Break protection. . . . . . Inhibits power to heater |
Control Accuracy. . . . . . . . +/-1ºF or +/- .5ºC |
Temperature Range. . . . . . .Ambient to 999ºF (535ºC) |
Cycle time. . . . . . . . . . . . . 0.33 seconds |
Manual control. . . . . . . . . . Adjustable from 0 to 100% |
Ramp Start. . . . . . . . . . . . .Duration 5 minutes |
Output. . . . . . . . . . . . . . . . Zero cross triac triggering |
Data Communication. . . . . .IBM PC compatible |
Compatibility. . . . . . . . . . . .Hot runner industrial standard compatible |
Accessories. . . . . . . . . . . . 600 to 240 volts step down transformers |
Power connectors 5, 8,12, zones |
Thermocouple connectors 5, 8,12 zones |
Floor Stands will support up to 48 zones |
Main Frames 5, 8,12, Stackable to 48 zones |
We Ship Our Kapton & Process Heaters To OEM’s & Industry World Wide